AMENDMENTS TO THE NFPA 101 LIFE SAFETY CODE / 1997

CHAPTER 33 - REFERENCED PUBLICATIONS

(See Appendix B for other referenced publications that are advisory and thus do not constitute part of the requirements of this Code.)

(Amd) 33-1 The following documents or portions thereof are referenced within this Code as mandatory requirements and shall be considered part of the requirements of this Code. The edition indicated for each reference is the edition of the date of the NFPA issuance of the document. Some of these mandatory documents might also be referenced in this Code for specific informational purposes and, therefore, are also listed in Appendix B.

The numbers in parentheses represent the paragraph numbers from the chapters of this Code that reference the given publication in a mandatory way.

The Fire Safety Code recognizes that it is sometimes impractical to continually upgrade existing buildings or installations to comply with all the requirements of the following referenced publications. Existing buildings or installations that do not comply with the provisions of the following referenced publications shall be permitted to be continued in service, provided the lack of conformity with these standards does not present a serious hazard to occupants as determined by the authority having jurisdiction.

(Amd) 33-1.1 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, PO Box 9101, Quincy, MA 02269-9101.

NFPA 10, Standard for Portable Fire Extinguishers, 1998 edition. (7-7.4.1)

NFPA 13, Standard for the Installation of Sprinkler Systems, 1996 edition. (6-2.4.12 Exception No. 1, 7-7.1.1, 7-7.4.2, 8-4.5.7, 8-7.5.3.7 Exception No. 1, 9-7.5.3.7 Exception No. 1, 12-3.5.3, 13-3.5.5, 16-1.5, 16-3.5.1 Exception, 17-1.5, 18-3.5.1 Exception No. 2, 19-2.2.1.2, 19-3.5.1 Exception No. 2, 21-2.2.1 Exception (b), 22-2.3.3.1 Exception No. 2 to (a), 22-2.3.5.2 Exception No. 3, 24-4.4.2.5(b), 25-4.4.2.5(b), 26-1.5.2, 27-1.5.2)

NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, 1996 edition. (7-7.1.1 Exception No. 2, 20-3.5.1 Exception No. 2, 21-2.2.1 Exception (b), 21-3.3.1 Exception No. 2 to (a), 22-2.3.5.2 Exception No. 1, 22-2.3.5.2 Exception No. 2, 23-2.3.5.1 Exception No. 1, 23-2.3.5.1 Exception No. 2)

NFPA 13R, Standard for the Installation of Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height, 1996 edition. (7-7.1.1 Exception No. 1, 16-3.5.1, 17-3.5.1, 18-3.5.1, 19-3.5.1, 20-3.5.1 Exception No. 1, 21-2.2.1 Exception (b), 21-3.3.1 Exception No. 2 to (a), 22-2.3.5.2 Exception No. 4, 22-2.3.5.2 Exception No. 5, 22-3.3.5.1 Exception No. 1, 23-2.3.5.1 Exception No. 3, 23-2.3.5.1 Exception No. 4, 23-3.3.5.1 Exception No. 1)

NFPA 14, Standard for the Installation of Standpipe and Hose Systems, 1996 edition. (7-7.4.2)

NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems, 1998 edition. (7-7.5, 7-7.6)

NFPA 30, Flammable and Combustible Liquids Code, See Sections 29-320-1a to 29-320-4a, inclusive, of the Regulations of Connecticut State Agencies known as the Connecticut Flammable and Combustible Liquids Code. (24-4.5.3.1(a), 24-4.5.5, 25-4.5.3.1(a), 25-4.5.5, 30-7.5, 31-7.5)

NFPA 30B, Code for the Manufacture and Storage of Aerosol Products, 1998 edition. (24-4.5.3.1(b), 24-4.5.5, 25-4.5.3.1(b), 25-4.5.5)

NFPA 40, Standard for the Storage and Handling of Cellulose Nitrate Motion Picture Film, 1997 edition. (8-4.6.1, 8-4.6.3 Exception, 9-4.6.1, 9-4.6.3 Exception)

NFPA 43B, Code for the Storage of Organic Peroxide Formulations, (See NPFA 432). (24-4.5.3.1(c), 25-4.5.3.1(c))

NFPA 43D, Code for the Storage of Pesticides, 1998 edition. (24-4.5.3.1(d), 25-4.5.3.1(d))

NFPA 45, Standard on Fire Protection for Laboratories Using Chemicals, 1996 edition. (6-4.4, 7-2.4, 10-3.2.3, 11-3.2.3, 26-3.2.3)

NFPA 54, National Fuel Gas Code, See Sections 29-329-1 to 29-329-4, inclusive, of the Regulations of Connecticut State Agencies known as the Connecticut Gas Equipment and Piping Code. (10-5.2.2 Exception, 10-7.5 Exception, 11-7.5, 16-5.2.2 Exception, 17-5.2.2 Exception, 18-5.2.2 Exception, 20-5.2.2 Exception, 30-5.2.2 Exception, 30-6.5.2.2 Exception, 30-7.6 Exception, 31-5.2.2 Exception, 31-6.5.2.2 Exception, 31-7.6 Exception)

NFPA 58, Standard for the Storage and Handling of Liquefied Petroleum Gases, See Sections 29-331-1 to 29-331-5, inclusive, of the Regulations of Connecticut State Agencies known as the Connecticut Liquefied Petroleum Gas and Liquefied Natural Gas Code. (8-7.1.4(d), 9-7.1.4(d))

NFPA 70, National Electrical Code, 1999 edition. (5-9.2.4, 6-2.4.12 Exception No. 3, 6-5.3.4, 7-1.2, 7-2.2, 7-6.1.4, 7-7.1.6, 8-4.3.4, 10-4.1.5, 14-5.1.2, 15-5.1.2, 15-5.1.2 Exception, 32-8.4.2)

NFPA 72, National Fire Alarm Code, 1996 edition. (5-2.1.8 Exception (c), 6-3.5.2, 6-3.5.3, 7-6.1.4, 7-6.2.8, 7-6.2.9, 7-6.2.10 Exception, 7-6.2.10 Exception No. 2, 7-6.3.2 Exception No. 2, 7-6.3.4, 7-6.3.5 Exception No. 2, 7-6.3.8, 7-6.4, 7-6.5.4, 7-7.2.1, 8-3.4.3.3, 10-3.4.2.3(a), 11-3.4.2.3 (a), 14-3.4.1.3, 15-3.4.1.3, 22-3.3.4.8, 23-3.3.4.6, 32-8.3.2)

NFPA 80, Standard for Fire Doors and Fire Windows, 1995 edition. (5-2.1.14(e), 6-2.3.2.1(a), 6-2.3.2.2, 12-3.6.3.5, 13-3.6.3.7)

NFPA 82, Standard on Incinerators and Waste and Linen Handling Systems and Equipment, 1994 edition. (7-5.2)

NFPA 88A, Standard for Parking Structures, 1998 edition. (16-3.5.4, 18-3.5.5)

NFPA 90A, Standard for the Installation of Air Conditioning and Ventilating Systems, 1996 edition. (6-2.6.1 Exception No. 2, 7-2.1)

NFPA 90B, Standard for the Installation of Warm Air Heating and Air Conditioning Systems, 1996 edition. (7-2.1)

NFPA 91, Standard for Exhaust Systems for Air Conveying of Materials, 1995 edition. (7-2.2)

NFPA 96, Standard on Ventilation Control and Fire Protection of Commercial Cooking Operations, 1998 edition. (7-2.3)

NFPA 99, Standard for Health Care Facilities, 1996 edition. (6-4.4 Exception, 7-2.4, 12-2.9.2, 12-2.10.2, 12-3.2.1, 12-3.2.2, 12-3.2.3, 12-3.2.4, 12-5.1.2, 12-5.1.3, 12-6.2.9.2, 12-6.3.2.1, 12-6.3.2.2, 13-3.2.2, 13-3.2.3, 13-3.2.4, 13-6.2.9.2, 13-6.3.2.1, 13-6.3.2.2)

NFPA 102, Standard for Grandstands, Folding and Telescoping Seating, Tents, and Membrane Structures, 1995 edition. (9-4.8.1)

NFPA 110, Standard for Emergency and Standby Power Systems, 1996 edition. (5-9.2.3, 7-1.3, 7-7.1.6, 32-8.4.2)

NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems, 1996 edition. (5-9.2.3, 7-1.4)

NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances, 1996 edition. (7-2.2)

NFPA 220, Standard on Types of Building Construction, 1995 edition. (6-2.1, 6-5.5.3 Exception, 12-6.1.6.2, 13-6.1.6.2)

NFPA 221, Standard for Fire Walls and Fire Barrier Walls, 1997 edition. (6-2.2.2)

NFPA 231, Standard for General Storage, 1995 edition. (24-4.5.3.1(e), 24-4.5.5, 25-4.5.3.1(e), 25-4.5.5)

NFPA 231C, Standard for Rack Storage of Materials, 1998 edition. (24-4.5.3.1(f), 24-4.5.5, 25-4.5.3.1(f), 25-4.5.5)

NFPA 231D, Standard for Storage of Rubber Tires, 1998 edition. (24-4.5.3.1(g), 24-4.5.5, 25-4.5.3.1(g), 25-4.5.5)

NFPA 241, Standard for Safeguarding Construction, Alteration, and Demolition Operations, 1996 edition. (12-7.8.2, 13-7.8.2)

NFPA 251, Standard Methods of Fire Tests of Building Construction and Materials, 1995 edition. (3-2, 6-2.3.1.1, 6-2.3.1.1 Exception No. 2, 8-4.5.7(e), 22-1.3, 23-1.3)

NFPA 252, Standard Methods of Fire Tests of Door Assemblies, 1995 edition. (3-2, 6-2.3.2.1(a), 6-2.3.2.3.1 Exception 2 to (b) and Exception to (c), 6-3.4.2(a))

NFPA 253, Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source, 1995 edition. (3-2, 6-5.6.1)

NFPA 255, Standard Method of Test of Surface Burning Characteristics of Building Materials, 1996 edition. (6-5.4.1, 6-5.5.1, 8-4.5.7(f))

NFPA 256, Standard Methods of Fire Tests of Roof Coverings, 1998 edition. (13-1.6.2 Exception, 15-1.6.3 Exception No. 1(a), 22-3.1.3.3 Exception to (a), (b), and (c), 23-3.1.3.3 Exception to (a), (b), and (c))

NFPA 257, Standard for Fire Tests of Window Assemblies, 1996 edition. (Section 3-2, 6-2.3.2.2(a))

NFPA 260, Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture, 1998 edition. (6-6.2(a))

NFPA 261, Standard Method of Test for Determining Resistance of Mock-Up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes, 1998 edition. (6-6.2(b))

NFPA 265, Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Wall Coverings, 1998 edition. (6-5.3.1.5, 6-5.3.1.5.1, 6-5.3.1.5.2, 6-5.3.5.1(e))

NFPA 266, Standard Methods of Test for Fire Characteristics of Upholstered Furniture Exposed to Flaming Ignition Source, 1998 edition. (6-6.3)

NFPA 418, Standard for Heliports, 1995 edition. (12-3.2.7)

NFPA 432, Code for the Storage of Organic Peroxide Formulations, 1997 edition. (33-1.1)

NFPA 701, Standard Methods of Fire Tests for Flame-Resistant Textiles and Films, 1996 edition. (6-6.1, 8-4.5.11, 8-7.5.3.4(c), 9-4.5.11, 9-7.5.3.4(c))

NFPA 703, Standard for Fire Retardant Impregnated Wood and Fire Retardant Coatings for Building Materials, 1995 edition. (6-5.8.1, 8-7.5.3.4(b), 9-7.5.3.4(b))

NFPA 1126, Standard for the Use of Pyrotechnics before a Proximate Audience, 1996 edition. (8-7.3, 9-7.3)

(Amd)33-1.2 Other Publications.

ANSI A14.3-1984, Safety Code for Fixed Ladders, American National Standards Institute, 11 West 42nd Street, New York, NY 10036 (5-2.9.2.1)

CABO/ANSI A117.1-1992, American National Standard for Accessible and Usable Buildings and Facilities, American National Standards Institute, 11 West 42nd Street, New York, NY 10036 (Section 3-2, 5-1.2, 5-2.12.3.5, 5-2.12.3.6, 5-10.1.3, 7-6.3.4)

ANSI A1264.1-1989, Safety Requirements for Workplace Floor and Wall Openings, Stairs and Railing Systems, American National Standards Institute, 11 West 42nd Street, New York, NY 10036 (5-2.9.2.1 Exception No. 2, 28-2.2.10 Exception)

ASME/ANSI A17.1, Safety Code for Elevators and Escalators, See Sections 29-192-A1 to 29-192-A58, inclusive, Sections 29-192-B1 to 29-192-B89, inclusive, and Sections 29-192-C1 to 29-192-C3, inclusive, of the Regulations of Connecticut State Agencies known as the Connecticut Safety Code for Elevators and Escalators. (5-2.12.2.4, 5-2.13.9, 5-2.13.11)

ASTM E136-1982, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (Section 3-2)

ASTM E1537, Standard Method for Fire Testing of Real Scale Upholstered Furniture Items, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (6-6.3)

ASTM E1590-1994, Standard Method for Fire Testing of Real Scale Mattresses, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (6-6.4)

ASTM F851-1983, Standard Test Method for Self-Rising Seat Mechanisms, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (8-2.5.5.1, 9-2.5.5.1)

Code of Federal Regulations 16, Part 1632 (6-6.2(c))

Connecticut Flammable and Combustible Liquids Code, Sections 29-320-1a to 29-320-4a, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 6-4.3.1(a), 33-1.1)

Connecticut Oil Burning Equipment Code, Sections 29-317-1a to 29-317-3a, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 7-2.2)

Connecticut Liquefied Petroleum Gas and Liquefied Natural Gas Code, Sections 29-331-1 to 29-331-5, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 6-4.3.1(c), 7-1.1, 33-1.1)

Connecticut Gas Equipment and Piping Code, Sections 29-329-1 to 29-329-4, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 6-4.3.1(b), 7-1.1, 7-2.2, 33-1.1)

Connecticut Safety Code for Elevators and Escalators, Sections 29-192-A1 to 29-192-A58, inclusive, Sections 29-192-B1 to 29-192-B89, inclusive, and Sections 29-192-C1 to 29-192-C3, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 7-4.2, 33-1.2)

Connecticut Tent and Portable Shelter Code, Sections 29-140-1a to 29-140-5a, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 29-292-1d)

UL 924, Standard for Safety Emergency Lighting and Power Equipment, Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062 (5-10.2.2)

UL 1975, Standard for Fire Tests for Foamed Plastic Used for Decorative Purposes, Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062 (6-6.7, 8-4.5.11, 8-7.4.3, 8-7.5.3.4(f), 8-7.5.3.4(g), 8-7.5.3.6, 9-7.4.3, 9-7.5.3.4(f), 9-7.5.3.4(g), 9-7.5.3.6)

(Effective May 1, 1999)