AMENDMENTS TO BOCA NATIONAL BUILDING CODE/1996
CHAPTER 35 - REFERENCED STANDARDS
| (Amd) AFPA |
American Forest and Paper Association
American Wood Council
1111 19th Street, NW
Suite 800
Washington, DC 20036 |
|
| Standard
reference number |
Title |
Referenced
in code section number |
| AF&PA NDS - 1997 |
National Design
Specification for Wood Construction - with the 1997 supplement; Design Values for Wood
Construction |
1808.1, 2303.1, 2304.1,
2305.14.1, 2305.15, 2306.4, 2306.4.5.1, 2306.4.5.2, 2306.4.6, 2306.4.6.1.1, 2306.4.6.2.1,
2312.1, 2312.4, 2313.3.1, 2313.3.2 |
| TR7-87 |
Basic Requirements for
Permanent Wood Foundation System |
1808.3, 1813.3, 2311.3.3 |
| (Amd) AISI |
American Iron and Steel Institute
Suite 1300
1101 17th Street, N.W.
Washington, DC 20036-4700 |
|
| Standard
reference number |
Title |
Referenced
in code section number |
| CFSD - ASD - 86 |
Specification for Design
of Cold-Formed Steel Structural Members - with 1989 Addendum |
1604.5.2, 2206.1,
2206.3, 2206.3.1 |
| CFSD - LRFD - 91 |
Load and Resistance
Factor Design Specification for Cold-Formed Steel Structural Members |
2206.1, 2206.3, 2206.3.1 |
| (Amd) ASCE |
American Society of Civil Engineers
345 East 47th Street
New York, NY 10017 |
|
| Standard
reference number |
Title |
Referenced
in code section number |
| ASCE 3 - 84 |
Specifications for the
Design and Construction of Composite Slabs |
1604.5.2, 1901.1,
2206.1.1 |
| ASCE 5/ACI 530/ TMS 402
- 95 |
Building Code
Requirements for Masonry Structures |
707.3, 1405.5, 1604.5.3,
Table 1610.3.3, 1705.5, Table 1705.5, 1812.3, Table 1812.3.2(1), 1815.4, 2101.1.1,
2101.1.2, 2101.2.2, 2105.3.1 |
| ASCE 6/ACI 530/ TMS 602
- 95 |
Specifications for
Masonry Structures |
1405.6, Table 1705.5,
2111.1.1 |
| ASCE 7 - 95 |
Minimum Design Loads for
Buildings and other Structures |
1604.1, 1604.2, 1606.4,
1606.6, 1606.8, 1607.3, 1607.5, 1608.1, 1609.1, 1609.1.1, Table 1609.7(6), 1610.1,
1610.3.7, 1612.2, 1612.3, 1612.4, 1613.1 |
| ASCE 8-SSD - LRFD/ASD -
90 |
Specification for Design
of Cold-Formed Stainless Steel Structural Members |
1604.5.2, 2206.1,
2206.3, 2206.3.1 |
| ASCE 19 - 95 |
Structural Applications
of Steel Cables for Buildings |
2207.2, 2207.2.1 |
| (Amd) ASME |
American Society of Mechanical
Engineers
345 East 47th Street
New York, NY 10017-2392 |
|
| Standard
reference number |
Title |
Referenced
in code section number |
| A13.1 - 81(85) |
Scheme for the
Identification of Piping Systems |
416.15.3 |
| A17.1 - 96 |
Safety Code for
Elevators and Escalators |
1108.5, 1110.2.2,
1610.6.5, 3001.2, 3001.3, 3004.4.1, 3004.4.2, 3004.5.1, 3005.3.2, 3006.2, 3012.3 |
| A17.3 - 96 |
Safety Code for Existing
Elevators and Escalators |
3013.1 |
| A90.1 - 92 |
Safety Standard for Belt
Manlifts ------ with A90.1a-95 Addendum |
3001.2, 3004.5.3 |
| B20.1 - 94 |
Safety Standard for
Conveyors and Related Equipment - with B20.1a-94 Addendum |
3001.2, 3004.5.5, 3010.3 |
| B31.3 - 93 |
Chemical Plant and
Petroleum Refinery Piping -- with B31.3a-93, B31.3b-94 & B31.3c-95 Addenda |
1007.5.4, 1014.11.4,
1016.5.1, 1101.1, 1102.1, 1103.2, 1105.1, 1106.1, 1106.2, 1107.2.2, 1107.3.2, 1107.4.1.1,
1107.4.2, 1108.2.1, 1108.7, 3006.3 |
| (Amd) CABO |
Council of American Building
Officials
Suite 201
5203 Leesburg Pike
Falls Church, VA 22041 |
| PLEASE NOTE THAT THE
TITLE OF THE CABO/ANSI A 117.1 STANDARD HAS BEEN CHANGED TO ICC/ANSI A117.1 |
|
| Standard
reference number |
Title |
Referenced
in code section number |
| ICC/ANSI A117.1 - 1998 |
Accessible and Usable
Buildings and Facilities |
1007.5.4, 1014.11.4,
1016.5.1, 1101.1, 1102.1, 1103.2, 1105.1, 1106.2, 1107.2.2, 1107.3.2, 1107.4.1.1,
1107.4.2, 1108.2.1, 1108.7, 3006.3 |
| (Amd) CODES |
| Standard
reference number |
Title |
Referenced
in code section number |
| |
State Fire Safety Code |
102.2, 201.3, 307.2,
307.8, Table 307.8(1), Table 307.8(2), 408.6, 412.3.7, 415.1, 416.14, 416.14.2, 417.1,
417.2.1, Table 417.2.1.1, 417.3, 417.5, 417.5.1, 417.5.2, 417.5.3, 417.5.5,417.6, 417.6.1,
417.6.3, 418.1, 418.2, 418.2.1, 418.3, 418.3.1, 418.3.2, 418.3.2.3, 418.3.3, 418.4, 418.5,
419.2.3, 705.2.1, 707.1.1, 901.2, 901.4, 901.7, 904.5, 915.1, 921.2, 3103.1, 3305.1,
3305.2, 3401.2, 3401.4, 3408.3.2, 3408.6.8.1, 3408.6.14, 3408.6.14.1 |
| IMC - 96 |
ICC International
Mechanical Code |
201.3, 307.8, 408.4.1,
408.5, 411.3, 416.9, 417.1, 417.3, 418.3.1.4, 418.3.2, 418.3.3, 418.3.4, 419.2, 419.2.1,
602.4.2, 602.4.3, 718.2, 723.2, 910.6, 914.1, 1005.7, 1203.1, 1208.3, 1209.1, 1210.3,
2305.12, 2702.2, 2801.2, 2802.1, 2802.3, 2804.1, 2805.2.3, 2805.2.4, 2808.3,2809.1,
3007.5, 3107.6, 3309.2, 3401.3, 3408.6.8, 3408.6.8.1 |
| IPC - 97 |
ICC International
Plumbing Code |
201.3, 408.4, 418.3.4,
602.4.3, 907.6.2, 11102.1, 1108.2, 1108.2.1, 1108.3, 1212.7, 1510.7.2, 1813.5.3, 2901.1,
2902.3, 2904.3, 2905.4.2, 2908.1, 2908.2, 3107.9, 3401.3 |
| OTFDC - 95 |
CABO One & Two
Family Dwelling Code |
310.6 |
| MEC - 95 |
CABO Model Energy Code |
1301.1 |
| (Amd) NFPA |
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269 |
|
| Standard
reference number |
Title |
Referenced
in code section number |
| 10 - 98 |
Portable Fire
Extinguishers |
921.2 |
| 11 - 98 |
Low Expansion Foam |
911.1, 911.5 |
| 11A - 94 |
Medium- and High
Expansion Foam Systems |
911.1, 911.5 |
| 12 - 98 |
Carbon Dioxide
Extinguishing Systems |
909.1, 909.5 |
| 12A - 97 |
Halon 1301 Fire
Extinguishing Systems |
912.1, 912.5 |
| (Note: NFPA
12B - 90 has been withdrawn and not replaced by NFPA.) |
| 13 - 96 |
Installation of
Sprinkler Systems |
409.2.2, 409.5, 412.3.6,
412.7, 416.4, 706.2, 906.2.1, 906.9.1, 907.2.1, 907.6.1, 915.5.1, 918.7.3, 1610.6.4,
3011.2.2 |
| 13D - 96 |
Installation of
Sprinkler Systems in One- and Two Family Dwellings and Manufactured Homes |
906.2.3 |
| 13R - 96 |
Installation of
Sprinkler Systems in Residential Occupancies Up to and Including Four Stories in Height |
906.2.2, 924.1 |
| 14 - 96 |
Standpipe and Hose
Systems |
915.1, 915.4.1, 915.12.1 |
| 15 - 96 |
Water Spray Fixed
Systems for Fire Protection |
908.1, 908.4 |
| 16 - 95 |
Installation of Deluge
Foam-Water Sprinkler and Foam-Water Spray Systems |
911.1, 911.5 |
| 17 - 98 |
Dry Chemical
Extinguishing Systems |
910.1, 910.5 |
| 17A - 98 |
Wet Chemical
Extinguishing Systems |
914.1, 914.5 |
| 24 - 95 |
Installation of Private
Fire Service Mains |
417.6.3, 906.9.1,
915.12.1 |
| 30 - 96 |
Flammable and
Combustible Liquids Code |
307.8, 418.3.2, 419.2.3 |
| 30A - 96 |
Automotive and Marine
Service Station Code |
408.6, 417.6.6 |
| 30B - 96 |
Manufacture and Storage
of Aerosol Products |
307.8 |
| 32 - 96 |
Drycleaning Plants |
418.3.4 |
| 33 - 95 |
Spray Application Using
Flammable and Combustible Materials |
307.8, 419.1 |
| 34 - 95 |
Dipping and Coating
Processes Using Flammable and Combustible Liquids |
307.8, 419.1 |
| 40 - 97 |
Storage and Handling of
Cellulose Nitrate Motion Picture Film |
411.1 |
| 61 - 95 |
Prevention of Fires and
Dust Explosions in Agricultural Food Products Facilities |
418.3.1 |
| (Note: NFPA
61A - 89, 61B - 89, 61C - 89 and 61D - 89 are replaced by NFPA 61 - 95.) |
| 65 - 93 |
Processing and Finishing
of Aluminum |
418.3.1 |
| 69 - 97 |
Explosion Prevention
Systems |
417.5.1.2 |
| 70 - 99 |
National Electrical Code
|
416.11, 416.14.6,
416.15.2, 421.10.1, 602.4.4, 1405.4.3, 2701.1, 2701.3, 2705.1, 2706.1, 2707.1, 2708.3
2805.2.5, 3102.6.3, 3102.13.1, 3107.6 |
| 72 - 96 |
National Fire Alarm Code |
403.6, 417.5.3, 918.1,
918.6, 918.7, 918.8.2, 918.9, 918.10, 919.1, 919.4.3, 919.8, 920.1, 920.6, 922.4, 924.1 |
| (Note: NFPA
71-89, 72E-90 and 74-89 are replaced by NFPA 72-93.) |
| 80 - 95 |
Fire Doors and Windows |
302.1.1.1, 717.2, 717,5,
1017.44 |
| 82 - 94 |
Incinerators and Waste
and Linen Handling Systems and Equipment |
2807.1 |
| 102 - 95 |
Assembly Seating, Tents,
and Membrane Structures |
3104.4 |
| 120 - 94 |
Coal Preparation Plants |
418.3.1 |
| 231C - 98 |
Rack Storage of
Materials |
507.1, Table 923.2 |
| 418 - 95 |
Standard for Heliports |
1511.3 |
| 495 - 96 |
Explosive Materials Code |
Table 307.8(1), 417.5.1,
904.5 |
| 651 - 98 |
Manufacture of Aluminum
Powder |
418.3.1 |
| 654 - 97 |
Prevention of Fire and
Dust Explosions in the Chemical, Dye, Pharmaceutical, and Plastics Industries |
418.3.1 |
| 655 - 93 |
Prevention of Sulfur
Fires and Explosions |
418.3.1 |
| 664 - 98 |
Prevention of Fires and
Explosions in Wood Processing and Woodworking Facilities |
418.3.1 |
| 701 - 96 |
Methods of Fire Tests
for Flame-Resistant Textiles and Films |
807.2, 807.2.2,
3102.6.4.2, 3103.3.2, 3104.5, 3105.4 |
| 704 - 96 |
Identification of the
Fire Hazards of Materials |
416.2, 416.15.1 |
| 8503 - 97 |
Pulverized Fuel Systems |
418.3.1 |
< Previous Next >
Order
| Contact | Online Brochure | Brochure (pdf) | Home