CONNECTICUT STATE FIRE SAFETY CODE

Sec. 25: Section 29-292-9d of the Regulations of Connecticut State Agencies is amended as follows:

Chapter Thirty-three of the Connecticut State Fire Safety Code is amended to read:

(Amd) 33-1.2 Other Publications.

ANSI A14.3-1984, Safety Code for Fixed Ladders, American National Standards Institute, 11 West 42nd Street, New York, NY 10036 (5-2.9.2.1)

CABO/ANSI A117.1-1992, [American National Standard for Accessible and Usable Buildings and Facilities, American National Standards Institute, 11 West 42nd Street, New York, NY 10036] See ICC/ANSI A117.1-1998 (Section 3-2, 5-1.2, 5-2.12.3.5, 5-2.12.3.6, 5-10.1.3, 7-6.3.4)

ANSI A1264.1-1989, Safety Requirements for Workplace Floor and Wall Openings, Stairs and Railing Systems, American National Standards Institute, 11 West 42nd Street, New York, NY 10036 (5-2.9.2.1 Exception No. 2, 28-2.2.10 Exception)

ASME/ANSI A17.1, Safety Code for Elevators and Escalators, See Sections [29-192-A1 to 29-192-A58, inclusive, Sections 29-192-B1 to 29-192-B89, inclusive, and Sections 29-192-C1 to 29-192-C3,] 29-192-1d to 29-192-6d, inclusive, of the Regulations of Connecticut State Agencies known as the Connecticut Safety Code for Elevators and Escalators. (5-2.12.2.4, 5-2.13.9, 5-2.13.11)

ASTM E136-1982, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (Section 3-2)

ASTM E1537, Standard Method for Fire Testing of Real Scale Upholstered Furniture Items, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (6-6.3)

ASTM E1590-1994, Standard Method for Fire Testing of Real Scale Mattresses, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (6-6.4)

ASTM F851-1983, Standard Test Method for Self-Rising Seat Mechanisms, American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959 (8-2.5.5.1, 9-2.5.5.1)

Code of Federal Regulations 16, Part 1632 (6-6.2(c))

Connecticut Flammable and Combustible Liquids Code, Sections 29-320-1a to 29-320-4a, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 6-4.3.1(a), 33-1.1)

Connecticut Oil Burning Equipment Code, Sections 29-317-1a to 29-317-3a, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 7-2.2)

Connecticut Liquefied Petroleum Gas and Liquefied Natural Gas Code, Sections 29-331-1 to 29-331-5, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 6-4.3.1(c), 7-1.1, 33-1.1)

Connecticut Gas Equipment and Piping Code, Sections 29-329-1 to 29-329-4, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 6-4.3.1(b), 7-1.1, 7-2.2, 33-1.1)

Connecticut Safety Code for Elevators and Escalators, Sections [29-192-A1 to 29-192-A58, inclusive, Sections 29-192-B1 to 29-192-B89, inclusive, and Sections 29-192-C1 to 29-192-C3,] 29-192-1d to 29-192-6d, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 7-4.2, 33-1.2)

Connecticut Tent and Portable Shelter Code, Sections [29-140-1a to 29-140-5a] 29-140-1b to 29-140-8b, inclusive, of the Regulations of Connecticut State Agencies, State of Connecticut Department of Public Safety, Office of State Fire Marshal, PO Box 2794, Middletown CT 06457-9294 (Section 29-292-1d)

ICC/ANSI A117.1-1998, BOCA International Inc., 4051 West Flossmoor Road, Country Club Hills, IL 60478-5795 (Section 33-1.2)

UL 924, Standard for Safety Emergency Lighting and Power Equipment, Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062 (5-10.2.2)

UL 1975, Standard for Fire Tests for Foamed Plastic Used for Decorative Purposes, Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062 (6-6.7, 8-4.5.11, 8-7.4.3, 8-7.5.3.4(f), 8-7.5.3.4(g), 8-7.5.3.6, 9-7.4.3, 9-7.5.3.4(f), 9-7.5.3.4(g), 9-7.5.3.6)