AMENDMENTS TO THE 1997 INTERNATIONAL PLUMBING CODE
CHAPTER 4 - FIXTURES, FAUCETS AND FIXTURE FITTINGS
TABLE 403.1
MINIMUM NUMBER OF PLUMBING FACILITIESa
(see Sections 403.2 and 403.3)
OCCUPANCY |
WATER
CLOSETS (Urinals see Section 419.2) |
LAVATORIES |
BATHTUBS/
SHOWERS |
DRINKING
FOUNTAINS (see Section 410.1) |
OTHERS |
A
S
S
E
M
B
L
Y |
|
Male |
Female |
|
|
|
|
Theaters |
1 per 125 |
1 per 65 |
1 per 200 |
- |
1 per 1,000 |
1 service sink |
Nightclubs |
1 per 40 |
1 per 40 |
1 per 75 |
- |
1 per 500 |
1 service sink |
Restaurants |
1 per 75 |
1 per 75 |
1 per 200 |
- |
1 per 500 |
1 service sink |
Halls,
museums, etc. |
1 per 125 |
1 per 65 |
1 per 200 |
- |
1 per 1,000 |
1 service sink |
Coliseums,
arenas |
1 per 75 |
1 per 40 |
1 per 150 |
- |
1 per 1,000 |
1 service sink |
Churchesb |
1 per 150 |
1 per 75 |
1 per 200 |
- |
1 per 1,000 |
1 service sink |
Stadiums,
pools, etc. |
1 per 100 |
1 per 50 |
1 per 150 |
- |
1 per 1,000 |
1 service sink |
Business
(see Section 403.2, 403.4 and 403.5) |
1
per 25 |
1 per 40 |
- |
1 per 100 |
1 service sink |
Educational |
1
per 50 |
1 per 50 |
- |
1 per 100 |
1 service sink |
Factory
and industrial |
1
per 100 |
1 per 100 |
(see Section
411) |
1 per 400 |
1 service sink |
High
hazard (see Sections 403.2 and 403.4) |
1
per 100 |
1 per 100 |
(see Section
411) |
1 per 1,000 |
1 service sink |
I
N
S
T
I
T
U
T
I
O
N
A
L |
Residential
care |
1
per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
Hospitals,
ambulatory nursinghome patientsc |
1
per roomd |
1 per roomd |
1 per 15 |
1 per 100 |
1 service sink
per floor |
| Day nurseries, sanitariums,
nonambulatory nursing home patients, etc.c |
1
per 15 |
1 per 15 |
1 per 15 c |
1 per 100 |
1 service sink |
Employees,
other than residential carec |
1
per 25 |
1 per 35 |
- |
1 per 100 |
- |
Visitors,
other than residential care |
1
per 75 |
1 per 100 |
- |
1 per 500 |
- |
Prisonsc |
1
per cell |
1 per cell |
1 per 15 |
1 per 100 |
1 service sink |
Asylums,
reformatories, etc.c |
1
per 15 |
1 per 15 |
1 per 15 |
1 per 100 |
1 service sink |
Mercantile
(see Sections 403.2, 403.4 and 403.5) |
1
per 500 |
1 per 750 |
- |
1 per 1,000 |
1 service sink |
R
E
S
I
D
E
N
T
I
A
L |
Hotels, motels |
1
per guest room |
1 per guest
room |
1 per guest
room |
- |
1 service sink |
Bed and
breakfast establishmentsg |
1
per 2 guest rooms |
1 per 2 guest
rooms |
1 per 2 guest
rooms |
- |
- |
Lodges |
1
per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
Multiple
family |
1
per dwelling unit |
1 per dwelling
unit |
1 per dwelling
unit |
- |
1 kitchen sink
per dwelling unit; 1 automatic clothes washer connection per 20 dwelling units |
Dormitories |
1
per 10 |
1 per 10 |
1 per 8 |
1 per 100 |
1 service sink |
One- and
two-family dwellings |
1
per dwelling unit |
1 per dwelling
unit |
1 per dwelling
unit |
- |
1 kitchen sink
per dwelling unit; 1 automatic clothes washer connection per dwelling unitf |
Storage
(see Sections 403.2 and 403.4) |
1
per 100 |
1 per 100 |
(see Section
411) |
1 per 1,000 |
1 service sink |
a The fixtures shown are based
on one fixture being the minimum required for the number of persons indicated or any
fraction of the number of persons indicated. The number of occupants shall be determined
by the building code.
b Fixtures located in adjacent buildings under the ownership
or control of the church shall be made available during periods the church is occupied.
c Toilet facilities for employees shall be separate from
facilities for inmates or patients.
d A single-occupant toilet room with one water closet and
one lavatory serving not more than two adjacent patient rooms shall be permitted where
such room is provided with direct access from each patient room and with provisions for
privacy.
e For day nurseries, a maximum of one bathtub shall be
required.
f For attached one- and two-family dwellings, one automatic
clothes washer connection shall be required per 20 dwelling units.
g Plumbing facilities in Use Group R-1 bed and breakfast
establishments shall be permitted to be accessed from hallways and corridors and to be
shared by guests.
< Previous Next >