AMENDMENTS TO THE BOCA NATIONAL BUILDING CODE/1996

CHAPTER 3 - USE OR OCCUPANCY

(Amd) 310.2 Definitions: The following words or terms shall, for the purposes of this section and as used elsewhere in this code, have the meanings shown herein.

Dwellings

(Add) Bed and breakfast establishment: A building that does not qualify as a one- or two-family dwelling unit in accordance with Section 310.5 and which contains only: The owner’s dwelling unit and guest rooms without permanent provisions for cooking, with a total building occupant load of not more than 16 persons (see Section 310.3.1).

(Add) Guest room: A space in a Use Group R-1 structure providing sleeping accommodations in one room, or in a series of closely associated rooms.

(Del) Residential board and care facilities. Delete without substitution.

(Add) 310.3.1 Use Group R-1 bed and breakfast establishments: A building that the owner occupies or that is adjacent to a building that the owner occupies as his/her primary place of residence, has a total building occupant load of not more than 16 persons including the owner-occupants, and has no provisions for cooking or warming food in the guest rooms. A Use Group R-1 bed and breakfast establishment shall not be permitted within a mixed use building. A fire evacuation plan shall be prominently posted on the inside of each guest room door.

(Add) 310.3.1.1 Kitchens in Use Group R-1 bed and breakfast establishments: Kitchens in Use Group R-1 bed and breakfast establishments shall be separated by ½-hour rated fire separation assemblies.

Exceptions:

  1. Fire separation assemblies shall not be required when the kitchen is protected by a limited area sprinkler system.

  2. Fire separation assemblies shall not be required when the kitchen is equipped with a listed residential range top extinguisher unit or an approved commercial kitchen hood with a listed, approved automatic fire suppression system.

  3. The structural members supporting the rated assemblies shall not be required to be fireresistance rated.

(Amd) 310.5 Use Group R-3 structures: This use group shall include all buildings arranged for occupancy as one- or two-family dwelling units, including not more than six lodgers or boarders per family and multiple single-family dwellings where each unit has an independent means of egress and is separated by a 2-hour fire separation assembly (see Section 709.0).

Exceptions:

  1. In multiple single-family dwellings that are equipped throughout with an approved automatic sprinkler system installed in accordance with Section 906.2.1 or 906.2.2, the fireresistance rating of the dwelling unit separation shall not be less than 1 hour. Dwelling unit separation walls shall be constructed as fire partitions (see Section 711.0).

  2. In multiple single-family dwellings that are equipped throughout with an approved automatic sprinkler system installed in accordance with Section 906.2.3, the fireresistance rating between each dwelling unit shall not be less than 1 hour and shall be constructed as a fire partition.